Description
Specifications
Parts List
Description
The outdoor units of the Daikin AURORA™ heat pump system have been redesigned to withstand the most extreme weather conditions. These multi-split systems can serve up to 4 rooms from a single outdoor unit. Ensuring year round comfort and desirable temperature for each space in a house and to have that temperature maintained no matter what the temperature outside – even when it is down to -13°F / -25°C.
Features
Features
- Inverter compressor
- 208/230/1 Power supply
- Cooling operating range: 14° to 115° F (w/ jumper cut)
- Heating operating range: -13° to 75° F (w/ drain pan heater as applicable)
- Sound pressures as low as 50 dB(A)
- Quiet operation
- Auto changeover
- Auto fan speed control
- Self-diagnostics with digital display
- Auto restart after power failure
- Anti -corrosion treatment on heat exchanger
- Parts: 12 Year Limited
California residents: see Proposition 65 Warning
Documents
picture_as_pdf installation instructions
picture_as_pdf submittal sheet
picture_as_pdf specification sheet
Specifications
Weight | 139 |
---|---|
Height | 28.9375 |
Length | 12.625 |
Width | 34.25 |
AHRI - Usage | Outdoor |
Brand | Daikin |
CFM | 1006-2150 |
Cooling Capacity | 18000 |
Country of Origin | CHN |
Cubic Measurement | 7.2412 |
Cycle/Hertz | 60 Hz |
Dimensional Weight | 170 |
EER | 10.1 |
ETL Listed | Yes |
Energy Star Rated | Yes |
Equipment Type | Heat Pump |
HSPF | 8.2 |
Heating Capacity | 18900 |
High Heat HP | No |
Liquid Line Fitting Type | Flare |
Liquid Line Size (OD) | 1/4" |
Maximum Overcurrent Protection (MOCP) | 20 |
Maximum Piping Height | 49 1/4' |
Maximum Piping Length | 164' |
Number of HVAC Zones | 2 |
OPT Code | 2MXL18QMVJU |
Package Height | 32 |
Package Length | 17.5 |
Package Weight | 147 |
Package Width | 41 |
Phase | Single |
Product Family | 2MXL_QMVJU |
Prop 65 | Yes |
Rated Load Amps (RLA) | 15.5 |
Refrigerant | R-410A |
Refrigerant Charge | 6.17 |
SEER | 14 |
Stage | Inverter |
Substantial Commodity | Steel; Copper; Aluminum |
Suction Line Fitting Type | Flare |
Suction Line Size (OD) | 3/8" |
Tonnage | 1.5 |
UL Listed | No |
UOM | EA |
UPC | See Optical |
Voltage | 208-230 VAC |