Description
Specifications
Parts List
Description
The Daikin DZ11 commercial heat pumps feature a powder-paint finish over heavy-gauge galvanized steel,providing premium durability and improved UV protection. The attractive louvered metal guard protects the coil from damage and strengthens the unit. The base pan is elevated to provide excellent water drainage and helps keep the coil away from debris that can collect inside the unit
Features
Features
- Designed for ground-level or rooftop mount
- An energy-efficient compressor with an internal relief valve
- A louvered cabinet made of heavy-gauge galvanized steel that protects the coil
- A factory-installed in-line filter drier
- A high-efficiency condenser coil made of corrugated aluminum fins and rifled refrigeration-grade copper tubing
- Refrigerant accumulator
- Two-stage energy efficient compressor with internal pressure relief valve
- High-capacity, steel-cased, bi-flow heat pump filter drier
- Liquid refrigerant return protection
- Check flowrater heating mode expansion device
- Reliable, time-initiated, temperature-terminated defrost control
- High and low pressure switches
- Discharge line muffler
- Brass liquid and suction line service valves mounted at a 90° angle with sweat connections and service ports
- High-efficiency copper tube/aluminum fin coil
- Complies with ASHRAE90.1-2016
- AHRI Certified; ETLListed
California residents: see Proposition 65 Warning
Documents
picture_as_pdf consumer literature
picture_as_pdf installation instructions
picture_as_pdf specification sheet
Specifications
Weight | 375 |
---|---|
Height | 41.5 |
Length | 35.5 |
Width | 35.5 |
AHRI - Usage | Outdoor |
Brand | Daikin |
CBU - Compressor Bearing Unit | Yes |
Compressor Type | Scroll |
Condenser Motor HP | 1 HP |
Condenser Motor Speeds | 1 (Single) |
Condenser Motor Type | PSC (Permanent Split Capacitor) |
Cooling Capacity | 115000 |
Corrosion Protected Coil | No |
Country of Origin | USA |
Cubic Measurement | 30.2664 |
Cycle/Hertz | 60 Hz |
EER | 11-11.2 |
ETL Listed | Yes |
Energy Star Rated | No |
Equipment Type | Heat Pump |
Full Load Amps | 5.6 |
Heating Capacity | 100000 |
IEER | 13.5 |
Liquid Line Fitting Type | Sweat or Braze |
Liquid Line Size (OD) | 5/8" |
Locked Rotor Amps (LRA) | 240 |
Maximum Overcurrent Protection (MOCP) | 70 |
Metering Device | TXV/TEV - Thermostatic Expansion Valve |
Package Height | 44 |
Package Weight | 374 |
Package Width | 37 |
Phase | Three |
Product Family | DZ11TA_3 |
Prop 65 | Yes |
Rated Load Amps (RLA) | 32.6 |
Refrigerant | R-410A |
Stage | Two |
Substantial Commodity | Steel; Copper; Aluminum |
Suction Line Fitting Type | Sweat or Braze |
Suction Line Size (OD) | 1 3/8" |
Tonnage | 10 |
UL Listed | No |
UPC | 663051566439 |
Voltage | 208-230 VAC |