Description
Specifications
Description
The BMPlus single stage, two stage, dual fuel and heat pump compatible control panels are designed for optimum performance and superior comfort and do not require the use of a dual fuel kit to be compatible with a dual fuel heat pump. The BMPlus can be set to select staging based on an adjustable time delay or based on outside air temperature.
Every panel features an adjustable supply air sensor, that can be mounted in the supply plenum, regardless of the coil/heat exchanger configuration, and three adjustable settings which protect the equipment from inefficient airflow.
You can use any four-wire thermostat with either manual or automatic changeover. The BMPlus will accept the first call from any thermostat and turn on the appropriate heating or cooling equipment while simultaneously closing the dampers to the non-calling zones. When another thermostat calls for the opposite mode, that call is held until the original calling zone is satisfied or until the opposing system timer of 20 min. (factory set) has expired, whichever comes first.
Once the call is satisfied all dampers will open and the system will shut down for four minutes. After four minutes the opposite mode will energize the system and close the dampers to the satisfied zones.
The "one zone" mode converts the zoning system to a single zone, all controlled and activated from the Zone One thermostat. This feature ensures energy efficiency during non-occupied periods.
The BMPlus 3000 is expandable up to seven zones using the XM-2 expansion panel
Every panel features an adjustable supply air sensor, that can be mounted in the supply plenum, regardless of the coil/heat exchanger configuration, and three adjustable settings which protect the equipment from inefficient airflow.
You can use any four-wire thermostat with either manual or automatic changeover. The BMPlus will accept the first call from any thermostat and turn on the appropriate heating or cooling equipment while simultaneously closing the dampers to the non-calling zones. When another thermostat calls for the opposite mode, that call is held until the original calling zone is satisfied or until the opposing system timer of 20 min. (factory set) has expired, whichever comes first.
Once the call is satisfied all dampers will open and the system will shut down for four minutes. After four minutes the opposite mode will energize the system and close the dampers to the satisfied zones.
The "one zone" mode converts the zoning system to a single zone, all controlled and activated from the Zone One thermostat. This feature ensures energy efficiency during non-occupied periods.
The BMPlus 3000 is expandable up to seven zones using the XM-2 expansion panel
California residents: see Proposition 65 Warning
Documents
picture_as_pdf consumer catalog
picture_as_pdf consumer literature
picture_as_pdf installation instructions
picture_as_pdf submittal sheet
picture_as_pdf specification sheet
Specifications
Weight | 2.7 |
---|---|
Height | 3 |
Length | 13 |
Width | 13 |
Brand | EWC® |
Country of Origin | USA |
Cubic Measurement | 0.2934 |
Dimensional Weight | 4 |
Display | No |
Display Options | No Display |
EAN | 0845484003525 |
Heat Pump Compatible | Yes |
Number of HVAC Zones | 3 |
Package Height | 3 |
Package Length | 13 |
Package Weight | 2.7 |
Package Width | 13 |
Prop 65 | Yes |
UOM | EA |
UPC | 845484003525 |
Voltage | 24 VAC |
Zone Capability | 2-3 Zones |